Minimalizacja strat mocy w trófazowym synchronicznym silniku reluktancyjnym
Artykuł w czasopiśmie
MNiSW
5
Lista B
| Status: | |
| Autorzy: | Banach Henryk |
| Rok wydania: | 2012 |
| Wersja dokumentu: | Drukowana | Elektroniczna |
| Język: | polski |
| Numer czasopisma: | 94 |
| Strony: | 139 - 143 |
| Efekt badań statutowych | NIE |
| Materiał konferencyjny: | NIE |
| Publikacja OA: | NIE |
| Abstrakty: | angielski |
| The three-phase reluctance motor has been investigated of rated power PN = 1,8 kW and nN = 1500 rpm. The motor was tested for the five selected frequencies fS = 50, 40, 30, 20, 10 Hz. The loadest was made for supplying with a rated voltage and with an optimal voltage. It was found that at optimaloperation of the motor, its efficiency can be significantly improved , in particular at part load. The optimalpower factor has constant value cosϕ = 0,5 and is independent from load and frequencies of the supply voltage. |