Dielectric Properties of Glass Beads with Talc as a Reference Material for Calibration and Verification of Dielectric Methods and Devices for Measuring Soil Moisture
Artykuł w czasopiśmie
MNiSW
140
Lista 2021
Status: | |
Autorzy: | Szerement Justyna, Saito Hironobu, Furuhata Kahori, Yagihara Shin, Szypłowska Agnieszka, Lewandowski Arkadiusz, Kafarski Marcin, Wilczek Andrzej, Majcher Jacek, Woszczyk Aleksandra, Skierucha Wojciech |
Dyscypliny: | |
Aby zobaczyć szczegóły należy się zalogować. | |
Rok wydania: | 2020 |
Wersja dokumentu: | Elektroniczna |
Język: | angielski |
Numer czasopisma: | 8 |
Wolumen/Tom: | 13 |
Numer artykułu: | 1968 |
Strony: | 1 - 12 |
Impact Factor: | 3,623 |
Web of Science® Times Cited: | 9 |
Scopus® Cytowania: | 12 |
Bazy: | Web of Science | Scopus | DOAJ |
Efekt badań statutowych | NIE |
Finansowanie: | This article has been supported by the Polish National Agency for Academic Exchange under Grant No. PPI/APM/2018/1/00048/U/001 and the National Centre for Research and Development under Grant No. BIOSTRATEG3/343547/8/NCBR/2017. |
Materiał konferencyjny: | NIE |
Publikacja OA: | TAK |
Licencja: | |
Sposób udostępnienia: | Otwarte czasopismo |
Wersja tekstu: | Ostateczna wersja opublikowana |
Czas opublikowania: | W momencie opublikowania |
Data opublikowania w OA: | 23 kwietnia 2020 |
Abstrakty: | angielski |
This paper presents dielectric measurements of talc, glass beads, and their mixtures under different moisture and salinity levels. The measurements were conducted using a prototype seven-rod probe (15 mm long central rod) connected to a single port of vector network analyzer. The samples were moistened with distilled water and KCl solutions in order to obtain six different moisture content levels. The complex dielectric permittivity was determined from vector network analyzer reflection-coefficient measurements based on the open-water-liquid calibration procedure. Next, the fitting of volumetric water content–real part of dielectric permittivity calibration curves was performed for each material at selected frequencies, and the obtained relations were compared with well-known calibration equations. Additionally, a salinity index for the tested materials was calculated. It was concluded that pure talc is not an optimal material for the calibration and verification of dielectric methods. The calibration curves obtained for glass beads and the mixtures of glass beads with talc gave results close to well-known reference calibration functions. Additionally, the addition of talc caused the data points to be less scattered. Moreover, the values of the salinity index for the tested materials were in a good agreement with literature data for sand. The obtained results indicated that glass beads with the addition of talc can be used as a reference material for the calibration and verification of dielectric methods and devices for soil moisture measurement. |