Wind Tunnel Testing of Plasma Actuator with Two Mesh Electrodes to Boundary Layer Control at High Angle of Attack
Artykuł w czasopiśmie
MNiSW
100
Lista 2021
Status: | |
Autorzy: | Gnapowski Ernest, Pytka Jarosław, Józwik Jerzy, Laskowski Jan, Michałowska Joanna |
Dyscypliny: | |
Aby zobaczyć szczegóły należy się zalogować. | |
Rok wydania: | 2021 |
Wersja dokumentu: | Elektroniczna |
Język: | angielski |
Numer czasopisma: | 2 |
Wolumen/Tom: | 21 |
Numer artykułu: | 363 |
Strony: | 1 - 13 |
Impact Factor: | 3,847 |
Web of Science® Times Cited: | 3 |
Scopus® Cytowania: | 3 |
Bazy: | Web of Science | Scopus |
Efekt badań statutowych | NIE |
Finansowanie: | We would like to offer our sincere thanks to the Institute of Technical Sciences and Aviation, The State School of Higher Education Chełm (Poland) for agreeing to conduct tests in the wind tunnel. |
Materiał konferencyjny: | NIE |
Publikacja OA: | TAK |
Licencja: | |
Sposób udostępnienia: | Witryna wydawcy |
Wersja tekstu: | Ostateczna wersja opublikowana |
Czas opublikowania: | W momencie opublikowania |
Data opublikowania w OA: | 7 stycznia 2021 |
Abstrakty: | angielski |
The manuscript presents experimental research carried out on the wing model with the SD 7003 profile. A plasma actuator with DBD (Dielectric Barrier Discharge) discharges was placed on the wing surface to control boundary layer. The experimental tests were carried out in the AeroLab wind tunnel where the forces acting on the wing during the tests were measured. The conducted experimental research concerns the analysis of the phenomena that take place on the surface of the wing with the DBD plasma actuator turned off and on. The plasma actuator used during the experimental tests has a different structure compared to the classic plasma actuator. The commonly tested plasma actuator uses solid/impermeable electrodes, while in the research, the plasma actuator uses a new type of electrodes, two mesh electrodes separated by an impermeable Kapton dielectric. The experimental research was carried out for the angle of attack α = 15° and several air velocities V = 5–15 m/s with a step of 5 m/s for the Reynolds number Re = 87,500–262,500. The critical angle of attack at which the SD 7003 profile has the maximum lift coefficient is about 11°; during the experimental research, the angle was 15°. Despite the high angle of attack, it was possible to increase the lift coefficient. The use of a plasma actuator with two mesh electrodes allowed to increase the lift by 5%, even at a high angle of attack. During experimental research used high voltage power supply for powering the DBD plasma actuator in the voltage range from 7.5 to 15 kV. |