Analysis of scaffolding harmonic excitation
Artykuł w czasopiśmie
MNiSW
100
Lista 2023
Status: | |
Autorzy: | Bęc Jarosław, Błazik-Borowa Ewa, Szer Jacek |
Dyscypliny: | |
Aby zobaczyć szczegóły należy się zalogować. | |
Rok wydania: | 2023 |
Wersja dokumentu: | Elektroniczna |
Język: | angielski |
Numer czasopisma: | 1 |
Wolumen/Tom: | 71 |
Strony: | 1 - 9 |
Impact Factor: | 1,2 |
Web of Science® Times Cited: | 1 |
Bazy: | Web of Science | BazTech |
Efekt badań statutowych | NIE |
Materiał konferencyjny: | NIE |
Publikacja OA: | TAK |
Licencja: | |
Sposób udostępnienia: | Witryna wydawcy |
Wersja tekstu: | Ostateczna wersja opublikowana |
Czas opublikowania: | W momencie opublikowania |
Data opublikowania w OA: | 26 lutego 2023 |
Abstrakty: | angielski |
Scaffolding is equipment usually used at construction sites. A scaffolding structure is lightweight and made of elements used many times. The characteristics of scaffolding make it susceptible to dynamic actions present at the structure or occurring nearby. A scaffolding structure of medium size was subjected to analysis in this paper. The structure FEM model was loaded with single force harmonic excitation with various frequencies ranging from 1 Hz to 12 Hz applied in one of many selected points on the scaffolding façade. In the first step, natural frequencies and mode shapes of the analyzed structure were calculated. Then the full dynamic analysis was carried out to obtain maximum displacements of selected control points. The relation of excitation force frequency and location to the amplitudes of generated displacement was observed. It was found that low excitation frequencies close to the natural frequencies of the structure produced vibrations ranging to large areas of the scaffolding surface. Higher excitation frequencies are usually less propagated at the scaffolding but still may produce some discomfort to the structure users in the vicinity of the excitation force location. Scaffolding is equipment usually used at construction sites. A scaffolding structure is lightweight and made of elements used many times. The characteristics of scaffolding make it susceptible to dynamic actions present at the structure or occurring nearby. A scaffolding structure of medium size was subjected to analysis in this paper. The structure FEM model was loaded with single force harmonic excitation with various frequencies ranging from 1 Hz to 12 Hz applied in one of many selected points on the scaffolding façade. In the first step, natural frequencies and mode shapes of the analyzed structure were calculated. Then the full dynamic analysis was carried out to obtain maximum displacements of selected control points. The relation of excitation force frequency and location to the amplitudes of generated displacement was observed. It was found that low excitation frequencies close to the natural frequencies of the structure produced vibrations ranging to large areas of the scaffolding surface. Higher excitation frequencies are usually less propagated at the scaffolding but still may produce some discomfort to the structure users in the vicinity of the excitation force location. |