Enhancing thermal performance of hot storage tanks through chimney-type electric heating and natural circulation
Artykuł w czasopiśmie
MNiSW
100
Lista 2024
Status: | |
Autorzy: | Beithou Nabil, Abdallatif Nassir, Khalid Mohammad Bani, Attar Hani, Alsaqoor Sameh, Alahmer Ali, Borowski Gabriel, As’ad Samer, Andruszkiewicz Artur, Al-dal’ain Reema |
Dyscypliny: | |
Aby zobaczyć szczegóły należy się zalogować. | |
Rok wydania: | 2024 |
Wersja dokumentu: | Drukowana | Elektroniczna |
Język: | angielski |
Numer czasopisma: | 3 |
Wolumen/Tom: | 18 |
Strony: | 151 - 160 |
Impact Factor: | 1,0 |
Web of Science® Times Cited: | 1 |
Scopus® Cytowania: | 2 |
Bazy: | Web of Science | Scopus | BazTech |
Efekt badań statutowych | NIE |
Finansowanie: | Applied Science Private University, Amman, Jordan, and the Tafila Technical University, Tafila, Jordan, and the Middle East University, Amman, Jordan |
Materiał konferencyjny: | NIE |
Publikacja OA: | TAK |
Licencja: | |
Sposób udostępnienia: | Otwarte czasopismo |
Wersja tekstu: | Ostateczna wersja opublikowana |
Czas opublikowania: | W momencie opublikowania |
Data opublikowania w OA: | 20 kwietnia 2024 |
Abstrakty: | angielski |
Hot storage tanks (HST) are known for their high energy consumption, attributed to variations in usage, heat dissipation within the tank, and heat losses to the surroundings. This study proposes a chimney-type electrically heated HST, which is investigated under static mode to enhance its thermal performance. Different natural circulation areas (chimney areas) with large (9.5 cm diameter), medium (2.5 cm diameter), and small (1.5 cm diameter) sizes were utilized to examine the effect of natural circulation on the HST performance. Additionally, the influence of chimney insulation on the HST performance was also studied. The experiments revealed that the chimney significantly affected the thermal stratification within the tank. Different chimney contact diameters (9.5 cm, 2.5 cm, and 1.5 cm) were tested, showing varying degrees of thermal stratification. The results indicated that smaller chimney contact diameters led to higher thermal stratification and more rapid heating of the top layer temperatures. However, the impact of insulation on thermal performance was inconclusive, suggesting the need for more effective insulation and further investigation into the dynamic mode of operation. The findings also highlighted the faster heating of the top outer layer compared to the larger diameter, emphasizing the significance of the chimney type electrical heater in the hot storage tank. |