A Numerical Evaluation of Multi-Tine Electrode Geometry and Monopolar and Bipolar Operating Modes on the Efficacy of Radiofrequency Ablation in a Hepatic Tumor Model
Artykuł w czasopiśmie
MNiSW
100
Lista 2024
| Status: | |
| Autorzy: | Gołębiowska Martyna, Miaskowski Arkadiusz, Gas Piotr |
| Dyscypliny: | |
| Aby zobaczyć szczegóły należy się zalogować. | |
| Rok wydania: | 2026 |
| Wersja dokumentu: | Drukowana | Elektroniczna |
| Język: | angielski |
| Numer czasopisma: | 12 |
| Wolumen/Tom: | 16 |
| Strony: | 1 - 21 |
| Impact Factor: | 2,9 |
| Web of Science® Times Cited: | 0 |
| Bazy: | Web of Science |
| Efekt badań statutowych | NIE |
| Materiał konferencyjny: | NIE |
| Publikacja OA: | TAK |
| Licencja: | |
| Sposób udostępnienia: | Witryna wydawcy |
| Wersja tekstu: | Ostateczna wersja opublikowana |
| Czas opublikowania: | W momencie opublikowania |
| Data opublikowania w OA: | 12 czerwca 2026 |
| Abstrakty: | angielski |
| This study presents a comprehensive computational evaluation of radiofrequency (RF) ablation efficacy and the spatial formation of thermal ablation zones within a 3D model of a liver tumor. By systematically comparing these configurations, the study aims to elucidate the physical mechanisms governing electromagnetic (EM) energy dissipation in hepatic tissue and to provide clear engineering guidelines for optimizing RF applicator selection and treatment planning in clinical practice. To reliably simulate the biophysical phenomena of the RF ablation procedure, a coupled electro-thermal model based on the finite element method and the Pennes bioheat equation was implemented. The research investigates six distinct applicator variants: conventional needle-type applicators and advanced expandable umbrella-type RF applicators equipped with four- and eight-tine electrodes, each evaluated in both monopolar and bipolar configurations. Numerical simulations were conducted for a standard 10 min ablation procedure at varying applied voltages to assess the specific absorption rate (SAR) distribution, transient heating dynamics, and the exact volumes of the resulting coagulation necrosis which were quantified using rigorous isotherms and the cumulative equivalent minutes at 43 ◦C (CEM43) thermal dose index. Volumetric analysis of the ablation zones revealed that bipolar multi-tine electrodes induce highly localized heat concentration. Conversely, monopolar multi-tine setups strongly disperse EM energy. The results demonstrated that, for conventional needle applicators, the monopolar configuration generated significantly larger necrosis zones than the bipolar operating mode. The RF applicator geometry and its operating mode directly dictate the spatial extent of liver tissue necrosis. Moreover, advanced numerical treatment planning is essential for optimizing SAR and CEM43 distributions and ensuring safe and complete hepatocellular carcinoma eradication |